Product Info for Unico 2802E SpectroQuest Spectrophotometer, standalone, 1.8nm Bandpass, 230V

Unico 2802E SpectroQuest Spectrophotometer, standalone, 1.8nm Bandpass, 230V is part of our big selection of UNICO Lab Equipment & Other. Remember to check out the entire variety of Lab Equipment & Other from UNICO that we have at everyday discounted prices. Browse our full product selection for the gear and products you want to tackle the task at hand.

Specifications for UNICO SQ2802 E Spectro-Quest Single Beam Scanning Spectrophotometer:

Wavelength Range: 190 - 1100 nm
Spectral Bandwidth: 1.8 nm / 0.5, 1, 2, 5 nm
Monochromator: Single beam Littrow type, grating 1200 lines/mm
Wavelength Accuracy: ±0.3 nm
Wavelength Repeatability: ±0.2 nm
Wavelength Calibration: automatic at start
Light Source: Tungsten Halogen/Deuterium Lamp
Detector: Solid Silicon Photodiode
Photometric Readout: 1/4 VGA 320X240 pixels backlit LCD
Photometric Range: 0 - 200%T -0.3 - 3.0A 0 - 9999C
Photometric Accuracy: ±0.3%T
Zero Drift: < 0.002A per hour after warm-up
Baseline Flatness: ±0.004A
Stability: 0.002A/h at 500 nm
Stray Light: < 0.15%T
Scanning Speed: Hi, Med., Low. Max. 1000 nm/min
Standard Sample Holder: 4-position Cell Holder
Analogue/Digital Output: Digital, RS232 Serial, Centronics Parallel
Dimensions: 620(L) x 400(W) x 280(H) mm
Weight: 22 kg / 48 lbs
Shipping Dimensions: 720(L) x 525(W) x 370(H) mm
Shipping Weight: 26 kg / 57 lbs
Power Requirements: 115V/60Hz or 230V/50Hz, switchable
Humidity Range: less than 85%
Safety Certificate: CE
 Model SQ2802A:
Wavelength Range:   190 - 1100 nm
Spectral Bandwidth:   1.8 nm / 0.5, 1, 2, 5 nm
Monochromator:   Single beam Littrow type, grating 1200 lines/mm
Wavelength Accuracy:   ±0.3 nm
Wavelength Repeatability:   ±0.2 nm
Wavelength Calibration:   automatic at start
Light Source:   Tungsten Halogen/Deuterium Lamp
Detector:   Solid Silicon Photodiode
Photometric Readout:   1/4 VGA 320X240 pixels backlit LCD
Photometric Range:   0 - 200%T -0.3 - 3.0A 0 - 9999C
Photometric Accuracy:   ±0.3%T
Zero Drift:   < 0.002A per hour after warm-up
Baseline Flatness:   ±0.004A
Stability:   0.002A/h at 500 nm
Stray Light:   < 0.15%T
Scanning Speed:   Hi, Med., Low. Max. 1000 nm/min
Standard Sample Holder:   8-position Cell Holder
Analogue/Digital Output:   Digital, RS232 Serial, Centronics Parallel
Dimensions:   620(L) x 400(W) x 280(H) mm
Weight:   22 kg / 48 lbs
Shipping Dimensions:   720(L) x 525(W) x 370(H) mm
Shipping Weight:   26 kg / 57 lbs
Power Requirements:   115V/60Hz or 230V/50Hz, switchable
Humidity Range:   less than 85%
Safety Certificate:   CE